list measurements ip-signaling-group
Issue 1 May 2002
7-201
555-233-143
list measurements ip-signaling-group
list measurements ip-signaling-group qualifer
Shows the 10 worst signaling groups for each hour of today, starting with the most
recent whole hour. The forms for the today and yesterday qualifiers are 24 pages,
one for each hour. The groups for each hour will be rank-ordered from worst to
least worst based on the Hour Average Latency.
Table 7-29.
list measurements ip-signaling-group command parameters
Action/ Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
list
measurement
s ip-signaling-
group
current-
hour
Shows the 10 worst
signaling groups for the
current hour.
last-hour
Shows the 10 worst
signaling groups for the
last full hour.
none
today
yesterday
Shows the 10 worst
signaling groups for each
hour of today, starting with
the most recent whole
hour, or yesterday.
none
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...