status bri-port
Issue 1 May 2002
7-297
555-233-143
ASAI
0-63
Established
blank
blank
This is a transitory state for ASAI
adjuncts. ASAI signaling is
connected at Layer 2 but the Layer 3
Restart procedure has not been
completed between switch and
adjunct.
1. Check the adjunct by following
the recommended repair
procedures of the manufacturer.
2. Repeat status bri-port and
determine whether the L2 state
of the signaling link is
L3-Established. If it is not,
follow normal escalation
procedures.
BRI
0-126
Established
ext#
blank
This is the normal state for non-MIM
initializing, fixed, and automatic TEI
BRI endpoints.
BRI,
ASAI
64-126
Established
blank
blank
This is a transitory state for
automatic TEI BRI endpoints that
support MIM initialization.
1. Verify that SPID administration
on the switch and the endpoint
are consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
L3-Established
.
2. Try replacing the endpoint.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
L3-Established
. If it is
not, follow normal escalation
procedures.
BRI
64-126
L3-Established
ext#
blank
This is the normal state for
automatic TEI BRI endpoints that
support MIM initialization.
Table 7-45.
Interpreting BRI-Port Status Reports —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...