status bri-port
Issue 1 May 2002
7-299
555-233-143
BRI
0-126
L3-Assigned
ext#
blank
This is a transitory state for BRI
endpoints that support MIM
initialization.
1. Wait 5 seconds and repeat the
command. If the state has not
changed, continue with Step 2.
2. Make sure SPID administration
on the switch and endpoint are
consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
L3-Established
. If it is
not, go to Step 3.
3. Try replacing the endpoint.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
L3-Established
. If it is
not, follow normal escalation
procedures.
Table 7-45.
Interpreting BRI-Port Status Reports —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page