PNC Cabling — Fiber Hardware
Issue 1 May 2002
2-7
555-233-143
Figure 2-2.
Typical DS1 CONV Connections to Remote EPNs
1. Place duplicate pairs in different carriers.
2. When removing two or more, the maximum cable distance between any
two remoted endpoints is 100 miles (161 km). For example, if one EPN is
75 miles (121 km) from the switch node cabinet, then no other EPN can be
more than 25 miles (40.2 km) from the same switch node cabinet.
3. Use a 846447637 within a carrier for a TN574, use a 847245750 within a
carrier for a TN1654.
Use a 846448645 within a cabinet between carriers for a TN574, use a
847245768 within a cabinet between carriers for TN1654.
Switch
Switch
Switch
Switch
Switch
TN570
circuit
pack
TN570
circuit
pack
TN570
circuit
pack
TN570
circuit
pack
TN573
circuit
pack
TN574
circuit
pack
TN574
circuit
pack
TN574
circuit
pack
TN573
circuit
pack
TN574
circuit
pack
TN573
circuit
pack
TN574
circuit
pack
TN574
circuit
pack
846448637
or
846448645
846448637
or
846448645
H600-348, G-( )
H600-348, G-( )
CSU
CSU
CSU
CSU
CSU
CSU
Cross
connect
field
Cross
connect
field
Cross
connect
field
846448637
DS1C
Fully duplicated
EPN
EPN
9823A
9823A
9823A
9823A
For direct
cross connect,
see text.
For direct
cross connect,
see text.
100 miles
100 miles
650 feet
650 feet
maximum
650 feet
650 feet
FL2P-XX
846448652
H600-348, G-( )
H600-348, G-( )
846448637
cydfep31 KLC 032001
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...