status hardware-group
Issue 1 May 2002
7-347
555-233-143
Field Descriptions
Hardware Group
Command State:
The state of a hardware-group command: active: testing is in progress;
canceled: testing has been canceled; complete the command has
completed and there is no testing going on.
Number of MOs
Tested:
The number of MOs in the specified group (refer to test hardware-group
command) that have had been tested by the current hardware-group
command. This includes every MO that either was actually tested or was
aborted due to resource contention.
Total Number of
MOs to be
Tested:
The total number of MOs in the group that was specified in the "test
hardware-group" command.
Percent
Complete:
A ratio of the number of MOs completed and the total number of MOs to
test in the command.
Elapsed Test
Time:
The duration of the hardware-group test. If a test was canceled and then
restarted this time excludes the cancel period. If the hardware-group
command has finished it will indicate the length of time it took to complete
the command. The time is displayed in the HH:MM:SS format where HH is
hours, MM is minutes, and SS is seconds.
Repetition
Number
The number of iterations that have been completed corresponding to the
‘repeat’ or the ‘continuously’ option.
Percentage of
Tests Passed:
The percentage of tests that passed.
Percentage of
Tests Failed:
The percentage of tests that failed.
Percentage of
Tests Aborted:
The percentage of tests that were aborted.
Command:
The hardware-group action object and qualifiers that were entered.
Test sequence:
This will display either short or long.
Test
repetition:
This will display either continuously or the keyword repeat along with the
repeat value entered.
Output
options:
This will display the selections that were chosen on the input form:
auto-page, background, or failures.
Hardware
options:
This will display the selections that were chosen on the input form
(all-ports).
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...