Maintenance Commands
555-233-143
7-350
Issue 1 May 2002
Sync Source
The current source of timing signals used for system synchronization
For systems with a Stratum 3 clock:
External – Normal operating condition
Internal – Another source besides the Stratum 3 clock, such as a
Tone-Clock circuit or circuit pack, is providing the master timing signal.
For systems with Stratum 4 timing:
Primary – The primary administered timing source
Secondary – The secondary administered timing source
Local – Another source besides the administered ones, such as a
Tone-Clock circuit or circuit pack, is providing the master timing signal.
# Logins
Number of current users
Cab
Cabinet number
Cabinet numbers can be related to port network numbers with the list
cabinet command.
Emerg Trans
The current setting of the switches on the PN’s Maintenance circuit packs
that control Emergency Transfer. See EMG-XFER in
.
The following states are available:
Auto-
Emergency Transfer is under system control and is not
currently activated (normal operating state).
Auto+
Emergency Transfer is under system control and is in effect.
On
Emergency Transfer has been manually activated. This setting
should only be in effect during an emergency.
Off E
mergency Transfer is manually prevented from occurring. This
setting should only be in effect when a technician is on site.
na
The setting of the switch in this PN is not available to the switch.
The Expansion Archangel Link (EAL) may be down.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...