status pnc
Issue 1 May 2002
7-373
555-233-143
Field Descriptions
Table 7-53.
Fault Class Field Descriptions
Fault Class
Priority
Description
MOs
FC_EAL
1
Number of PNs with EALs down
EXP-PN
FC_INL
2
Number of PNs with LINL, RINL, or EI-SNI neighbor
link faults
EXP-PN
SN-CONF
FC_HW
3
Number of PNs affected by hardware faults in a link
having an EI as an endpoint (Endpoints can be
determined with list fiber-link.)
EXP-INTF
SN-CONF
FIBER-LK
SNI-BD
DS1C-BD
FC_PER
4
Number of PNs affected by SNI peer link faults for
SNIs connected to EIs
SNI-PEER
FC_DS1
5
Number of PNs affected by DS1C facility faults
DS1FAC
FC_SNIL
6
Number of inter-switch-node fibers affected by peer
or neighbor link faults
SNI-PEER
FC_SNIHW
7
Number of inter-switch-node fibers affected by
hardware faults
SN-CONF
SNI-BD
FIBER-LK
Major Alarms,
Minor Alarms,
Warning Alarms
The number of major, minor, or warning alarms logged against
DS1C-BD, SNI-BD, SNC-BD, EXP-INTF, FIBER-LK, DS1C-FAC,
SNC-LINK, SN-CONF, SNC-REF, SYNCH, and SNI-PEER on the
indicated PNC.
Switch Node
Locations
The locations of all Switch Nodes comprising the indicated PNC.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...