test eda-external-device-alrm
Issue 1 May 2002
7-431
555-233-143
Output
For the following output example the command that was entered was
test
external-device-alarm all:
The responses are displayed on a test-by-test basis with one line of data
displayed for each test result.
Field Descriptions
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance object that is
being tested.
MaintenanceN
ame
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the MO. This is an administered more
descriptive name of the external device alarm
Test No
The actual test that is being executed.
Result
The result of the individual test – PASS, ABORT, FAIL,NO BOARD, DISABLED,
EXTRA BD.
Error Code
A system-generated number that tells why the release failed or aborted. A
detailed list of the codes according to “Test No.” is provided for each MO.
test eda-external-device-alrm all
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
03major EXT-DEV CMS1 120 PASS
03A2102 EXT-DEV CMS2 120 FAIL
01major EXT-DEV UPS1 120 PASS
01minor EXT-DEV UPS1 120 PASS
01c1201 EXT-DEV UPS1 120 PASS
03A2101 EXT-DEV CC temp 120 PASS
01c1202 EXT-DEV Audix1 120 PASS
03minor EXT-DEV Audix2 120 FAIL
04major EXT-DEV unknown 120 FAIL
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...