Maintenance Commands
555-233-143
7-444
Issue 1 May 2002
test journal-printer
test journal-printer pms-log | wakeup-log
[short | long] [repeat-number| clear] [schedule]
The test journal-printer command performs hardware diagnostics on the link
between the switch and a specified journal printer link to either the PMS-log
printer or the wakeup-log printer.
Parameters
One of the two journal printers must be specified:
Output
Background maintenance activity on a link can interfere with testing and recovery
of a particular component of the link. For example, as part of a test, maintenance
software may busyout a component of the link, causing the link to drop. The
system may then perform frequent attempts to re-establish the link. This can
delay recovery of the component, since it must be idle for certain tests to take
place. Busying out the link will prevent the system from these attempts to set up
the link. Remember that a busyout will tear down a link if it is not already down.
pms-log
This specifies the link to the Property Management System printer, whose
maintenance name is PMS-PRNT.
wakeup-log
This specifies the wakeup-log printer, whose maintenance name is JNL-PRNT.
Maintenance
Name
PMS-PRNT designates the PMS-log printer. JNL-PRNT designates the
wakeup-log printer.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...