Maintenance-Object Repair Procedures
555-233-143
8-6
Issue 1 May 2002
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order shown in the table below. For example, by
clearing error codes associated with the Battery and Battery Charger Query test
(#5), you may also clear errors from other tests in the testing sequence. Refer to
the appropriate sections of this chapter for descriptions of each test.
NOTE:
The following tests apply to J58890CE, J58890CF, and J58890CH.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Battery & Battery Charger Query test (#5)
X
X
ND
AC Power Query test (#78)
X
X
ND
Power Unit Query test (carrier E) (#127)
X
X
ND
Power Unit Query test (carrier D) (#127)
X
X
ND
Power Unit Query test (carrier A) (#127)
X
X
ND
Power Unit Query test (carrier B) (#127)
X
X
ND
Power Unit Query test (carrier C) (#127)
X
X
ND
Emergency Transfer Query test (#124)
X
X
ND
Cabinet Temperature Query test (#122)
X
X
ND
External Alarm Lead Query test (#120)
X
X
ND
Analog Ring Generator Initialization test (#117)
X
X
ND
Analog Ring Generator Query test (#118)
X
X
ND
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...