ADX16A-BD (AUDIX Circuit Pack)
Issue 1 May 2002
8-25
555-233-143
ADX16A-BD (AUDIX Circuit Pack)
The ADX16A-BD MO represents a TN566/TN2169 EMBEDDED AUDIX circuit
pack combination operating in control-link (CL) mode. For circuit-pack-level
problems, see
‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872
. Port-level
maintenance is covered by ADX16A-PT.
EMBEDDED AUDIX consists of two circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
that tests a circuit pack’s components related to the TDM-bus interface. The
AUDIX system has an extensive maintenance strategy that is described in
EMBEDDED AUDIX System Maintenance, 585-300-110.
MO’s Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
Full Name of MO
ADXCL-BD or
\ADX16A-BD
MINOR, or
WARNINGS
test board UUCSS sh
AUDIX circuit pack
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...