ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 May 2002
8-35
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port UUCSSpp command.
b. The circuit pack has been logically administered but not physically
installed. The alarm will be cleared when the circuit pack is installed.
c. The circuit pack has been removed or has been insane for more than
11 minutes. To clear the error, reseat or replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only one analog circuit pack in
the system has this problem, then replace the circuit pack. If only analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, check the ringing generator.
e. AUDIX is not available to the switch. Check the AUDIX system, referring to
EMBEDDED AUDIX System Maintenance, 585-300-110.
f. The TDM bus is out of service. See
Table 8-12.
EMBEDDED AUDIX Analog Line/Control Link Error Log Entries
Error
Type
Aux
Data
Associated Test
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
40977
None
18
0
busyout station
extension
WARNING
ON
release station extension
23 (b)
0
None
WARNING
OFF
130 (c)
None
WARNING
ON
test port UUCSSpp sh
257 (d)
40973
None
513 (e)
Any
None
1025 (f)
Looparound test
(#161)
MINOR
WARNING
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON
test port UUCSSpp l r 2
1281
Conference test
(#7)
MINOR
WARNING
ON
test port UUCSSpp l r 2
1537
NPE Crosstalk
test (#6)
MINOR
WARNING
ON
test port UUCSSpp l r 2
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...