Maintenance-Object Repair Procedures
555-233-143
8-44
Issue 1 May 2002
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The port’s battery feed chip is unable to supply sufficient power to sense the
external device alarm. This may occur when the test is performed at the same
time that the external device contact closure occurred.
1. Before retesting, enter test external-device-alarm port UUCSSpp to
determine whether the port is reporting an EXT-DEV failure. Wait until the
port has no EXT-DEV failures before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
PASS
The port’s battery feed chip is able to provide power to the external device
alarm to detect contact closure.
Table 8-17.
Test #35 Battery Feed Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page