ALARM-PT (ALARM PORT)
Issue 1 May 2002
8-45
555-233-143
Station Status and Translation Audits and
Updates Test (#36)
For an analog line port that is administered as an external alarm, this test is
limited to updating the software with the switchhook state.
Table 8-18.
Test #36 Station Status and Translation Audits and Updates
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port received an EXT-DEV failure during the test. The test has been
aborted.
1. Before retesting, enter test external-device-alarm port UUCSSpp to
determine whether the port is reporting an EXT-DEV failure.
2. If the port has no EXT-DEV failures, retry the command at 1-minute
intervals up to 5 times.
1006
ABORT
This port has been busied out by command.
1. Check Error Log for Error Type 18 (port busied out). If present, release the
port with the release port UUCSSpp command and run the test again.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
This failure does not indicate a hardware problem. The switchhook audit failed,
this condition may occur when the audit is performed at the same time that the
terminal equipment goes off-hook.
1. Before retesting, enter test external-device-alarm port UUCSSpp to
determine whether the port is reporting an EXT-DEV failure. Wait until the
port has no EXT-DEV failures.
2. If the port has no EXT-DEV failures, retry the command at 1-minute
intervals up to 5 times.
7
FAIL
The translation update failed. This does not indicate a hardware problem but
may be an internal software error.
PASS
The software and the port processor have the same status.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...