Maintenance-Object Repair Procedures
555-233-143
8-88
Issue 1 May 2002
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t
for the port).
2. If either list config or display port indicate that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct for the test, and no action is necessary.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service state
failed or the attempt to put the port in connection with a tone source failed (this
could be a Tone-Clock problem). The Tone-Clock and Tone Detectors could
be having a communication problem. (For example, the companding modes
could be out of synchronization.)
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The port’s battery feed chip is unable to supply sufficient power to the terminal
equipment. This may occur when the test is performed at the same time that
the terminal equipment goes off-hook.
1. Use status station to determine when the port is available for testing.
When the port becomes available for testing, retry the command at
1-minute intervals a minimum of five times.
2. If the test continues to fail, determine whether the customer is experiencing
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
PASS
The port’s battery feed chip is able to provide power to the station equipment to
detect on-/off-hook. However, the battery feed chip may still be unable to
provide power for touch-tones. If tones are heard when buttons are pressed,
then the battery feed chip is functioning correctly; otherwise, replace the circuit
pack because this port is defective. User-reported troubles on this port should
be investigated by using other port tests, by examining station wiring, by
examining the station, and by ensuring that the terminal is correctly translated
as off-premises or on-premises.
NOTE:
This test always passes for circuit packs TN712 prior to Vintage 14 and
TN742 prior to Vintage 6.
Table 8-35.
Test #35 Battery Feed Test Results —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...