ANL-LINE, ANL-NE-L (8-Port Analog Line)
Issue 1 May 2002
8-95
555-233-143
1005
ABORT
The test was aborted due to a configuration problem. This code occurs under
either of the following conditions:
■
This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, a modem pool
member or music on hold).
■
The circuit pack is one of the following:
— TN742 vintage 13, 14, or 15
— TN769 vintage 3, 4, or 5
1018
ABORT
Test disabled via administration. The default for the
Test?
field on the is y;
thus, you may want to determine why this field has been set to “n” on this
station (this may be due to the ringing application test 48, which can be
customer or terminal disturbing).
1. To enable the test for a particular station, enter change station extension
and set the ‘Test?’ field on the ‘Station Form’ to ‘y.’
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t
for the port).
2. If either list config or display port indicate that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct for the test, and no action is necessary.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service state
failed or the attempt to put the port in connection with a tone source failed (this
could be a Tone-Clock problem). The Tone-Clock and Tone Detectors could
be having a communication problem. (For example, the companding modes
could be out of synchronization.)
1. Retry the command at 1-minute intervals up to 5 times.
Table 8-37.
Test #47 Loop Around and Conference Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...