Maintenance-Object Repair Procedures
555-233-143
8-98
Issue 1 May 2002
Station Present Test (or Ringing Application Test)
(#48)
This test provides a burst of ringing current to the terminal equipment and detects
that current flows. This test is to ascertain whether or not terminal equipment is
connected to the port.
This test may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing is disturbing the customer or the terminal equipment,
it should be disabled using the Tests field of the station administration screen.
However, on some releases of the software, this action disables Tests #6, 47, and
35, as well as Test #48.
Table 8-38.
Test #48 Station Present Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test were not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp to determine the station’s extension.
Enter status station extension to determine the service state of the port. If
the port is active, it will be unavailable for certain tests. Wait until the port
is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
3. Check for phone left off-hook or for wiring problems.
1004
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is active, then
the port is unavailable for certain tests. Wait until the port is idle before
retesting.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort and the port is idle, escalate the problem.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...