Maintenance-Object Repair Procedures
555-233-143
8-108
Issue 1 May 2002
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Resolve any TONE-PT errors in the error log.
2. If there are no TONE-PT errors, retry the command at 1-minute intervals
up to 5 times.
3. If the test continues to abort, escalate the problem.
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This causes
noisy and unreliable connections.
1. Issue the display port UUCSSpp and the status station extension
commands to determine whether the station is idle.
2. If the station is idle, issue the test port UUCSSpp command for this port.
3. If the test continues to fail, issue the busy port UUCSSpp and the release
port UUCSSpp commands, and then retest.
4. If the test still fails, replace the board.
PASS
The port can correctly conference multiple connections. Investigate
user-reported troubles on this port by running other port tests; by examining
station, trunk, or external wiring; or by inspecting the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This result could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the list
configuration command, and resolve any problems.
2. If the board is correctly inserted, issue the busy board UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command.
This should re-establish the link between the internal ID and the port. If
not, verify that a valid board is inserted.
Table 8-41.
Test #7 Conference Circuit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...