AN-LN-PT (Analog Line Port)
Issue 1 May 2002
8-113
555-233-143
1
FAIL
The switchhook audit failed. This result does not indicate a hardware problem.
The other updates were not performed because of this failure. This may occur
if the audit is performed at the same time the terminal equipment goes off-hook.
1. Use the status station extension command to determine when the port is
available.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to fail, escalate the problem.
5
FAIL
The message waiting lamp update failed. This may be an internal software
error. The translation and ringer updates were not performed because of this
failure.
7
FAIL
The translation update failed. There may be an internal software error. The
ringer update was not performed because of this failure.
8
FAIL
The ringer update failed. There may be an internal software error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, escalate the problem.
PASS
The software and the port processor have the same status. Investigate
user-reported troubles on this port by running other port tests, by examining
station wiring, or by inspecting the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This result could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the list
configuration command, and resolve any problems.
2. If the board is correctly inserted, issue the busy board UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command.
This should re-establish the link between the internal ID and the port. If
not, verify that a valid board is inserted.
Table 8-43.
Test #36 Station Status and Translation Audits and Updates —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...