Maintenance-Object Repair Procedures
555-233-143
8-134
Issue 1 May 2002
Super Frame Match Inquiry Test (#211)
The super frame is a means by which the Speech Processor (SP) synchronizes
with the 140AY device on the announcement circuit pack. If the super frame is not
synchronized, the SP will not be able to properly process record/playback
requests. Both the SP and the hardware generate a super frame pulse. When
these two pulses are out of synch, the SP sets a flag to indicate the mismatch.
When this test is run, the state of this flag is returned.
Clock Match Inquiry Test (#212)
This test determines the state of the clock-generating circuitry on the
Announcement circuit pack. This circuitry is used to synchronize the
announcement board with the TDM clock carried on the EPN’s backplane.
Table 8-50.
Test #211 Super Frame Match Inquiry
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
If Error Type 1538 is present in the Error Log, follow the maintenance strategy
recommended for this Error Type.
2100
ABORT
Could not allocate the necessary system resources to run this test.
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Test failed. Announcement playbacks should sound corrupted.
1. Reset the circuit pack via the reset board UUCSS command and then run
this test again. If the test continues to fail, replace the circuit pack (see
Warning).
2. If there are recurring alarms on this circuit pack caused by this test failing,
replace the circuit pack even if step 1 works.
!
WARNING:
Replacing the circuit pack causes a loss of integrated announcements.
See
‘‘Essential Service Information’’ on page 8-120
of AN-LN-PT MO.
PASS
The speech processor can properly process record/playback requests.
User-reported troubles on this circuit pack should be investigated using other
circuit pack and port tests. Refer to “ANN-PT” for a description of the port tests.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...