ATM-BCH (ATM B-Channel Trunk)
Issue 1 May 2002
8-171
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call
state. Possible causes:
■
Received a DISConnect or RELease COMplete message with
cause value 52 (outgoing calls barred)
■
Received a DISConnect or RELease COMplete message with
cause value 54 (incoming calls barred)
■
Outgoing call renegotiated by the far end to another B channel in the
absence of SETUP message glare
■
Near end attempted a call on a B channel that the far end has
marked OOS
When running the short test sequence, pay close attention to the results of
the Call State Audit test (#257).
Table 8-69.
ATM-BCH Error Log entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSppp
Any
None
test port UUCSSppp
18
0
busyout trunk grp/mbr
release trunk
grp/mbr
129 (
None
WARNING
OFF
test port UUCSSppp
130 (
test port UUCSSppp
257(
Any
Service State Audit test
(#256)
test port UUCSSppp
513(
Any
None
WARNING
OFF
test port UUCSSppp
769(
Any
Service State Audit test
(#256)
test port UUCSSppp
1793(
)
Any
None
test port UUCSSppp
3073(
)
Any
Service State Audit test
(#256)
test port UUCSSppp
3585(
Any
None
none
3841(
Any
None
WARNING
OFF
none
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...