ATM-DCH (ATM D-Channel Port)
Issue 1 May 2002
8-185
555-233-143
Signaling Link Board Check (#643)
This nondestructive test checks the health of the ATM TN230X trunk circuit pack
hardware. The test runs on a periodic or scheduled basis, during initialization
testing, and upon demand.
NOTE:
The board-level maintenance is handled independently of the ATM-CES
signaling link maintenance, raising the possibility of inconsistent states.
Table 8-77.
Test #643 Signaling Link Board Check
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
Retry the command at 1-minute intervals up to 5 times.
8
FAIL
The TN230X circuit pack is not in-service.
Check the Error Log for ATM-TRK errors and resolve any using
(Circuit Emulation Service Circuit Pack)’’
PASS
The ATM TN230X circuit pack is in-service.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...