Maintenance-Object Repair Procedures
555-233-143
8-196
Issue 1 May 2002
1. Test the ATM-EI circuit pack (test board UUCSS) and investigate
further based on each test’s results. If every test passes, the error
was a transient problem.
Aux Data values: For Setup and Add Party connection request failure type,
the port-network and the angel number of the destination ATM-EI circuit
pack are logged Aux Data values in the form XXYYY, where
■
port-network number = XX
■
angel number = YYY
Aux Data values for WSP Setup (XX = WSP number, YYY = location code).
Since you need to know the slot number also,
Data to slot numbers.
Table 8-82.
Error Type 1024-1151 Aux Data values (XXYYY) converted to
slot number
Slot
Carrier
A
B
C
D
E
Failure type
Failure type
Failure type
Failure type
Failure type
Slot
#
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
1
28
528
828
66
566
866
98
598
898
34
534
834
02
502
802
2
29
529
829
67
567
867
99
599
899
35
535
835
03
503
803
3
30
530
830
68
568
868
100 600
900
36
536
836
04
504
804
4
31
531
831
69
569
869
101 601
901
37
537
837
05
505
805
5
56
556
856
70
570
870
102 602
902
38
538
838
06
506
606
6
57
557
857
71
571
871
103 603
903
39
539
839
07
507
607
7
58
558
858
72
572
872
104 604
904
40
540
840
08
508
808
8
59
559
859
73
573
873
105 605
905
41
541
841
09
509
809
9
60
560
860
74
574
874
106 606
906
42
542
842
10
510
810
10
61
561
861
75
575
875
107 607
907
43
543
843
11
511
811
11
62
562
862
76
576
876
108 608
908
44
544
844
12
512
812
12
63
563
863
77
577
877
109 609
909
45
545
845
13
513
813
13
88
588
888
78
578
878
110 610
910
46
546
846
14
514
814
14
89
589
889
79
579
879
111 611
911
47
547
847
15
515
815
15
90
590
890
80
580
880
112 612
912
48
548
848
16
516
816
16
91
591
891
81
581
881
113 613
913
49
549
849
17
517
817
17
92
592
892
82
582
882
114 614
914
50
550
850
18
518
818
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...