ATM-EI (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-209
555-233-143
20MM
FAIL
The failure codes only apply to a system equipped with an ATM Switch. The
letters “MM” refer to the distant or far-end EPN, and “NN” to the near-end
ATM-EI under test.
1. The test tone was detected correctly in reverse direction (data sent from
port network MM was detected correctly in the EPN where the circuit pack
under test resides, but not the opposite direction).
2. Test the active Tone-Clock on the “MM” EPN and the EPN where the
ATM-EI under test resides (test tone-clock UUCSS). This determines if
dial tone is supplied.
3. Ensure that the ATM address of the active ATM-EI circuit pack under test
matches the ATM address on the ATM switch for the port to which this
circuit pack is connected. Refer to ATM Installation, Upgrades, and
Administration for Avaya MultiVantage Solutions book for the procedure to
check the ATM port address on the ATM switch.
4. Run Test #241 on the active ATM-EI in port network MM. If this test fails
with Error Code 20NN or 40NN, go back to step 2.
If the address was the same, replace the active ATM-EI circuit pack on port
network MM.
If this test fails with Error Code 10NN or 30NN, replace ATM-EI circuit pack
with the initial problem.
30MM
FAIL
The failure codes only apply to a system equipped with an ATM Switch. The
letters “MM” refer to the distant or far-end EPN, and “NN” to the near-end
ATM-EI under test.
The test failed for the first connection from the ATM-EI board under test to
another EPN, and the test tone was detected correctly in the forward direction
(data sent from the EPN where the circuit pack under test resides was detected
correctly in port network MM, but not the opposite direction).
1. Test the active Tone-Clock on the “MM” EPN and the EPN where the
ATM-EI under test resides (test tone-clock UUCSS). This determines if
dial tone is supplied.
2. Ensure that the ATM address of the ATM-EI circuit pack under test
matches the ATM address on the ATM switch for the port to which this
circuit pack is connected. Refer to for the procedure to check the ATM port
address on the ATM switch.
3. Run Test #241 on the active ATM-EI in port network MM. If this test fails
with Error Code 10NN or 30NN, go back to step 2.
If the address was the same, replace the active ATM-EI circuit pack on port
network MM.
If this test fails with Error Code 20NN or 40NN, replace ATM-EI circuit pack
with the initial problem.
Table 8-85.
Expansion Interface 2-Way Transmission Test (#241) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...