Maintenance-Object Repair Procedures
555-233-143
8-214
Issue 1 May 2002
ATM Board Error Query Test (#1259)
This test is nondestructive. The ATM circuit pack firmware maintains counters for
some of the on- and off-board errors. The maintenance software queries the
board for its health information to do error analysis. These alarms have assigned
priority: if a higher priority alarm occurs, the remaining alarms are not reported to
the software (through the inline errors), avoiding unnecessary up-link, in-line error
message traffic. This is run as a part of a craft demand test sequence periodic
testing, initialization, and error analysis.
ANY
FAIL
The transmitted data packet was not received correctly by the Packet Interface
circuit pack. The failure can be in the ATM-EI under test, the DS1 CONV circuit
packs, or the intervening Center Stage components.
1. Retry the command at 1-minute intervals up to five times.
2. If the test continues to fail, replace the circuit pack.
PASS
The Packet Interface test passed.
Table 8-89.
ATM Board Error Query Test (#1259)
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response to the test was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
XXYY
FAIL
On-board hardware or off-board signaling errors on the board. XX indicates
the on-board hardware error, and YY indicates the off-board errors on the as
shown in
1. Resolve any errors in error logs.
PASS
No service effecting errors or alarms were detected on the circuit pack.
Continued on next page
Table 8-88.
Packet Interface Test (#598) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...