ATM-EI (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-219
555-233-143
Table 8-91.
ATM Board Framer Loop-Around Test (#1260)
Error
Code
Test
Result
Description / Recommendation
1002
ABORT
The system could not allocate timeslots for the test. The system could be
under heavy traffic conditions or it could have timeslots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
2. Verify that at least one Tone Detector resides in this EPN. (Even without a
TTR-LEV error, the tested circuit pack’s EPN could be missing a Tone
Detector.)
If missing, the test always aborts for this circuit pack, without harming the
system.
NOTE:
A TN2182 Tone-Clock circuit pack must be of vintage B or newer. If an
earlier vintage circuit pack resides in an EPN, this test always aborts
with this abort code.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up to 3
times.
1015
ABORT
The ATM-EI circuit pack has not been busied out.
1. Busyout the ATM-Expansion Interface circuit pack, then repeat the test
board UUCSS long command.
1031
ABORT
If the ATM Expansion Interface circuit pack is in an EPN and is on the active
PNC, this test cannot be executed.
1. If PNC Duplication is enabled, attempt to make the standby PNC active
with the reset pnc interchange command.
2. If the PNC Interchange is successful, rerun the test.
1033
ABORT
The ATM-EI circuit pack is absent.
1. Issue the list atm pnc command to verify that switch recognizes the circuit
pack.
2. Retry the command.
1139
ABORT
The packet bus in the EPN where this ATM-EI board resides has a major alarm
against it. This test needs to use the alarmed EPN’s packet bus.
1. Resolve any PKT-BUS problems.
2. Retry the command.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...