Maintenance-Object Repair Procedures
555-233-143
8-220
Issue 1 May 2002
1141
ABORT
The Packet Interface circuit pack is out of service.
1. Resolve any PKT-INTF problems.
1394
ABORT
The ATM-EI board is out of service and the test cannot be run. This condition
is due to a change in the ATM-EI board’s ability to communicate with the ATM
switch.
1. Run Test #241. If it does not pass, see repair procedures for
Interface 2-Way Transmission Test (#241)’’
1395
ABORT
This test cannot be run on an ATM-EI circuit pack if it is part of the B-side PNC
and duplicated PNC is not enabled.
1. If this test needs to run on this ATM-EI circuit pack, enable PNC duplication
with the change system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
1407
ABORT
This test cannot be run on an ATM-EI board that is on the active PNC because
it cannot be busied out. This error code indicates that PNC duplication is
enabled.
1. Attempt to perform a PNC interchange with the reset pnc interchange
command.
2. If the PNC interchange is successful, busyout the original ATM-Expansion
Interface circuit pack with the busyout board UUCSS (address of the
original ATM-EI board) command.
3. Retry the command.
2000
ABORT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2060
ABORT
The link on the packet bus being used to perform the test has failed.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, resolve any PKT-INTF errors.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
Table 8-91.
ATM Board Framer Loop-Around Test (#1260) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...