Maintenance-Object Repair Procedures
555-233-143
8-222
Issue 1 May 2002
6
FAIL
A previously-established loop around was not released.
1. Issue the reset board UUCSS command.
2. Retry the command at 1-minute intervals up to 3 times.
3. If this test continues to fail, replace the ATM-EI circuit pack.
4. Test the new ATM-EI circuit pack (test board UUCSS long).
PASS
The ATM-EI board is functioning properly, however this test does not verify that
the optical portion of the lightwave transceiver is functioning.
0
NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues, if
applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, the NCE chip on board could be bad.
Replace the board and retest.
Table 8-91.
ATM Board Framer Loop-Around Test (#1260) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page