Maintenance-Object Repair Procedures
555-233-143
8-238
Issue 1 May 2002
Notes:
a. Aux Data values for Setup and Add Party (XX = Port Network, YYY =
location code).
Aux Data values for WSP Setup (XX = WSP number, YYY = location code).
is a list of UNI 3.1 location codes:
b. Error Types 257 to 300 — These error type numbers are used to
determine the destination PNC connection number of an ATM Network
connection that is experiencing an impaired path. The connection number
is obtained by subtracting 256 from the number that is shown in the Error
Type field. See the following example:
ERROR TYPE field = 263
Subtract = 256
PNC destination connection # = 7
The AUX DATA field contains the originating and destination EPN number
(XXYY). Where XX = the originating EPN #, and YY = the destination
EPN # for example:
1. AUX DATA = 302
3 = orig
2 = dest
2. Example AUX DATA = 1510
15 = orig
10 = dest
Table 8-100.
Location codes from Aux Data values
Setup
(Location
Code)
Add
Party
(Location
Code)
WSP
Setup
(location
Code)
Location Code Meaning
0
500
800
User
1
501
801
Private network serving the local user
2
502
802
Public network serving the local user
3
503
803
Transit network
4
504
804
Public network serving the remote user
5
505
805
Private network serving the remote user
7
507
807
International network
10
510
810
Network beyond interworking point
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...