Maintenance-Object Repair Procedures
555-233-143
8-270
Issue 1 May 2002
Table 8-112.
Test #417 Test Synchronization Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
1115
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error
PASS
The synchronization maintenance component circuit pack parameters have
been successfully updated. The system should be synchronized after
successful execution of this test.
1. If synchronization problems still exist, refer to the Error Log to obtain
information regarding the source of the problem.