Aux Data XX
Aux Data YY
Table 8-127.
Aux Data XX for ATM Board Error Query Test (#1259)
If XX=
Then
1
ATM framer chip failed
2
NCE chip failed
3
LANHO critical error
4
TDM Programmable Logic Device failed
5
Every on-board DSP failed
6
Receive Network Processor failed
7
Transmit Network Processor failed
8
Memory read failed
9
Dual UART chip failed
10
LANHO receive parity error
11
LANHO FIFO overflow error
12
LAN bus time out
13
LANHO Xmit FIFO overflow error
14
One or more on-board DSPs failed
Continued on next page
Table 8-128.
Aux Data YY for ATM Board Error Query Test (#1259)
If YY=
Then
15
Back plane clock failed
16
Loss of signal
17
Loss of frame
18
MS alarm indication signal error
19
MS remote defect indicator error
20
Loss of pointer
21
Path signal level mismatch