Maintenance-Object Repair Procedures
555-233-143
8-320
Issue 1 May 2002
AXA12-RS/ADX8D-RS/AXD12-RS
(AUDIX Reserve Slots)
There are no tests associated with these MOs. Both the test board and busyout
board commands abort when either is attempted on a reserved slot. An error
message indicates that the slot is associated with the circuit pack that the TN568
is emulating, but the requested operation is not valid. If there are errors logged
against these MOs, see
‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872
The TN568 circuit pack connects to the switch through a single slot in the
backplane; however, the number of slots physically occupied by the circuit pack is
supplied by the board when inserted. The TN568 is 2 slots wide: the functional
slot and a reserve slot. The reserve (blank) slot to the left of the functional slot is
a place holder on the switch and has no interaction with the switch.
These MOs are place holders for the extra slot needed for the EMBEDDED
AUDIX board. Each instance of these MOs represents a reserve slot associated
with the respective circuit pack mode in which the TN568 (EMBEDDED AUDIX) is
working. They are used for EMBEDDED AUDIX and emulation of respective port
types.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial
Command to
Run
Full Name of MO
AXA12-RS
NONE
NONE
TN568 12-port analog reserve slot
ADX8D-RS
NONE
NONE
TN568 8-port digital reserve slot
AXD12-RS
NONE
NONE
TN568 12-port digital reserve slot
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...