Maintenance-Object Repair Procedures
555-233-143
8-340
Issue 1 May 2002
Figure 8-12.
Path of the BRI Port Local LAN Loop Around
Table 8-144.
Test #618 BRI Port Local LAN Loop Around
Error
Code
Test
Result
Description / Recommendation
1015
ABORT
The port is not in the out-of-service state.
1. Display the BRI Port Status form via the status bri-port PCSSpp
command to determine what stations or adjuncts are on this port.
2. Use the extension shown on this form in the status station command to
determine whether the station or adjunct is active.
3. If so, wait until it is idle, and then busyout the port (using the busyout port
PCSSpp command) to place it in the out-of-service state and repeat this
test.
!
WARNING:
Since the “busyout” command is destructive, execution of this command
prior to the port being idle causes every call associated with BRI
endpoints and every transaction associated with ASAI or Avaya adjuncts
on the port to be torn down. Note that 3
rd
-party calls established by an
ASAI or Avaya adjunct remain connected even though the port is taken
out-of-service.
Continued on next page
BRI LINE
CIRCUIT
PACK
PACKET
INTERFACE
PACKET BUS
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . .
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...