CARR-POW (Carrier Power Supply)
Issue 1 May 2002
8-405
555-233-143
Notes:
a. Refer to “POWER” section for a description of this test.
b. Refer to “AC-POWER” section for a description of this test.
c. Refer to “EMG-XFER” section for a description of this test.
d. Refer to “CABINET” section for a description of this test.
e. Refer to “EXT-DEV” section for a description of this test.
f. Refer to “RING-GEN” section for a description of this test.
OLS Recycle Test (#126)
This test is destructive.
This test removes power from the specified carrier and causes every circuit pack
in the recycled carrier to be removed and inserted. These actions cause every
call originating from or terminating to circuit packs in this carrier to be dropped.
The pair of OLSs in the specified carrier is recycled. Both OLSs in the carrier are
turned off for 2 seconds and then back on again. After the OLSs have been
turned back on, the test queries an EPN’s Maintenance circuit pack for the status
of the pair of OLSs in the specified carrier. If both OLSs are on and functioning,
then the test passes. If both OLSs are not on and functioning, the test fails, and
BOTH OLSs are turned off.
Table 8-164.
Test #126 OLS Recycle Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1366
ABORT
Indicates that the active Tone-Clock for the EPN is in requested carrier.
1. If duplicated Tone-Clock boards or IPSIs exist, issue the set tone-clock
command to switch Tone-Clocks, otherwise the power cannot be cycled.
2. If the switch succeeds, rerun the test.
1367
ABORT
Indicates that the active Expansion Interface link for the EPN is in requested
carrier.
1. If duplicated EIs exist, issue the reset pnc interchange command to
switch EIs, otherwise the power cannot be cycled.
2. If the switch succeeds, rerun the test.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...