Maintenance-Object Repair Procedures
555-233-143
8-460
Issue 1 May 2002
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
Table 8-185.
Test #0 Dial Tone Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the command display port UUCSSpp to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is active, then it is unavailable for certain tests. Wait until the port
is idle before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABORT
System resources required to run this test were not available. This could be
due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is active, then it is unavailable for certain tests. Wait until the port
is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1005
ABORT
Trunk has been administered as incoming-only; dial tone can only be obtained
on outgoing trunks. This is a normal condition.
1018
ABORT
Test has been disabled via administration.
1. Verify that the
Maintenance Tests?
field on the Trunk Group form is
set to “n.” To enable the test, issue the change trunk-group x command
where x equals the number of the trunk group to be tested. Then change
the entry in the
Maintenance Tests?
field on the form to “y.”
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...