DS1-BD (DS1 Interface Circuit Pack)
Issue 1 May 2002
8-629
555-233-143
Translation Update Test (#146)
The Translation Update test sends the circuit pack-level information specified by
System Administration to the DS1 Interface circuit pack. Translation includes the
following data administered for a DS1 Interface circuit pack (see output of display
ds1 UUCSS command): DS1 Link Length between two DS1 endpoints,
Synchronization Source Control, All Zero Suppression, Framing Mode, Signaling
Mode, time-slot number of 697-Hz tone, time-slot number of 700-Hz tone, etc.
If a TN767E or later DS1 circuit pack is combined with a 120A CSU module or a
T1 sync splitter to form an integrated CSU module, this test will also send the
administration for this Integrated CSU to the circuit pack to assure the board’s
translations are correct. The administration of the CSU module is done using the
DS1 circuit pack administration form. Translation for the CSU module includes
the following data: Transmit LBO, Receive ALBO, Supply CPE loop-back jack
Power?, and so forth.
Table 8-253.
Test #146 Translation Update Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system software error.
1. Enter the display ds1 UUCSS command to verify the DS1 Interface circuit
pack translation.
PASS
Translation data has been downloaded to the DS1 Interface circuit pack
successfully.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the add ds1 UUCSS
command to administer the DS1 interface if it is not already administered.
2. If board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the link between the internal ID and the port.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...