Maintenance-Object Repair Procedures
555-233-143
8-726
Issue 1 May 2002
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence
and only one test path in the test sequence. Once the test sequence begins,
every test in the test sequence is executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administered as a digital
station. These include stations with an emulated digital voice terminal and
stations with an emulated digital voice terminal and a linked data module.
Stand-alone data modules and data adaptors in stand-alone mode are not
supported by the TN800 circuit pack. Circuit pack maintenance is covered by
E-DIG-BD.
MO’s Name (in
Alarm Log)
Alarm Level
Initial SAT Command to
Run
1
(a) (b)
1.
Where UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC); C is the
carrier designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit
pack resides (1 – 21); and pp is the 2-digit port number (01, 02, 03, ...).
Full Name of MO
E-DIG-STA
MINOR
test port UUCSSpp l
Emulated Digital St.
E-DIG-STA
WARNING
test port UUCSSpp sh
Emulated Digital St.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...