EMG-XFER (Emergency Transfer)
The Emergency Transfer MO monitors the position of the Emergency Transfer
switch(es) on the PPN’s SYSAM circuit pack(s) and the EPNs’ Maintenance
circuit packs. It does not monitor whether the system is actually in Emergency
Transfer.
Emergency Transfer (ET) provides the ability to connect designated analog
phones to CO trunks when the switch cannot provide minimal phone service.
Each EPN’s cabinet (PPN and EPNs) has its own ET capability, and there is one
EMG-XFER MO for each cabinet or stack of single-carrier cabinets.
ET is controlled either automatically by the system, or manually, depending on the
setting of the ET switches as described below.
Emergency Transfer Status
The status cabinet UU command shows the location of the ET switches and the
current status of ET in the designated cabinet as follows:
MO’s Name (in
Alarm Log)
Alarm Level
Initial SAT Command to
Run
1
1.
UU is the universal cabinet number as listed in the PORT field of the Alarm or Error Log.
Full Name of MO
EMG-XFER
MAJOR
test environment UU
Emergency Transfer
EMG-XFER
WARNING
test environment UU
Emergency Transfer
auto+
ET is invoked and under system control.
auto-
ET is not in effect and is under system control (normal
operating state).
unavailable
The switch setting(s) is not available.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...