Maintenance-Object Repair Procedures
555-233-143
8-740
Issue 1 May 2002
Table 8-288.
Test #124 Emergency Transfer Query Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with Error Code 2000, check for system
powering problems with the PN’s A carrier. Resolve every AC-POWER
and CARR-POW alarm in a multicarrier cabinet system or DC-POWER
alarm in a single-carrier cabinet system. Then, repeat the test.
3. If the test continues to ABORT with a 2000 Error Code, resolve every or
MAINT (Maintenance circuit pack) error in an PN. Then, repeat the test.
2029,
2319,
2320,
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
17,
18,
20,
33,
65,
289
FAIL
Emergency Transfer is manually turned OFF (Emergency Transfer switch off).
1. Place the switch in the AUTO position.
34,
290
FAIL
Emergency Transfer is manually turned ON (Emergency Transfer switch on).
1. Place the switch in the AUTO position.
PASS
System software has control of Emergency Transfer within this cabinet. If
Emergency Transfer is currently invoked (the emergency transfer LED is on),
the cause could be a major alarm.
1. The following list shows the error types that can cause Emergency
Transfer. If any of these errors appear in the log, then see
, and resolve these error types first:
■
Error Type 3585 Aux Data 121
■
Error Type 2305, Aux Data 40800
2. If none of the previous errors appear in the log, then check the Emergency
Transfer hardware.
3. On an EPN, if Emergency Transfer is invoked while call processing is
permitted, verify that the current limiter card (982LS) is in the correct slot
on the backplane. If the current limiter card is not in the correct slot, move
it to the correct location, and rerun Test #124.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...