ETR-PT (Enhanced Tone Receiver Port)
Issue 1 May 2002
8-759
555-233-143
Table 8-297.
Test #42 Tone Detection Verification Test
Error
Code
Test
Result
Description / Recommendation
none
ABORT
The system was not able to allocate all the resources needed for this test, or
there was an Internal system error.
1
ABORT
The system could not allocate all the resources needed to test the tones.
1001
ABORT
The system was unable to put the ETR-PT in the appropriate mode to test it.
1002
ABORT
The system could not allocate time slots for the test connection. This situation
could occur when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM-BUS with the test tdm command.
1. Retry the command at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a Tone-Clock for the test connection. This may
be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the TONE-BD or TONE-PT in
the PN where the test aborted.
2. If a new Tone-Clock has been inserted, allow about 1 minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Circuit pack’s response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2006
ABORT
This abort code indicates that the active Tone-Clock circuit pack or a Tone
Detector circuit pack may not be functioning properly.
1. Test the active Tone-Clock circuit pack in the PN with the test tone-clock
UUC command.
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1–122
FAIL
DTMF digits were not detected correctly.
1. Run the short test sequence with the test port UUCSSpp sh r 1
command.
2. If the problem persists, the system is still operating properly but capacity is
reduced. To restore performance to normal, replace the circuit pack with
the defective ETR-PT.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...