Tone Detector Audit/Update Test (#43)
A Digital Signal processor sanity audit is performed on the ETR-PT.
102
FAIL
2225-Hz Modem Answer Tone was not detected correctly. This impacts
call-classification operation.
1. Run the short test sequence via the test port UUCSSpp sh r 1 command.
2. If the problem persists, the system can still operate properly but capacity is
reduced. In order to restore performance to normal, replace the circuit
pack containing the defective port. Follow the procedures described in
‘‘TONE-BD (Tone-Clock Circuit)’’ on page 8-1659
for replacing a
Tone-Clock circuit pack.
130
FAIL
Forward or Backward MFC signals were not correctly generated or detected.
This will impact MFC calls.
1. Run the short test sequence via test port UUCSSpp sh r 1.
2. If the problem persists, the system can still operate properly but capacity
will be reduced. In order to restore performance to normal, replace the
TN2182/TN2312AP circuit pack containing the defective ETR-PT. Follow
the procedures described in
‘‘TONE-BD (Tone-Clock Circuit)’’ on page
for replacing a Tone-Clock circuit pack.
PASS
Tone detection verification is successful. The ETR port is able to
detect/generate all necessary tones.
Table 8-298.
Test #43 Tone Detector Audit/Update Test
Error
Code
Test
Result
Description / Recommendation
none
ABORT
The system could not allocate all the resources needed for this test.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Table 8-297.
Test #42 Tone Detection Verification Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...