Table 8-306.
Test #241 Expansion Interface 2-Way Transmission Test
Error
Code
Test
Result
Description / Recommendation
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors. Enter display errors and follow associated repair
procedures for TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out of service.
1. Enter display errors and follow associated repair procedures for TTR-LEV
errors in the error log. Even if there are not TTR-LEV errors, there may not
be a tone detector available on the network that contains the circuit pack
being tested. Verify that there is at least one tone detector on this network.
If not, this test will always abort for this EI circuit pack. This will not harm
the system in any way.
NOTE:
S8700 Multi-Connect systems require that Tone Detector circuit packs
(TN768) must be of vintage “B” or newer. If older Tone Detector circuit
packs are installed in the system, this test will always abort with this
code.
2. Enter display errors and follow associated repair procedures for
TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 3
times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...