Maintenance-Object Repair Procedures
555-233-143
8-800
Issue 1 May 2002
Table 8-307.
Test #242 Expansion Interface Lightwave Transceiver Looparound
Error
Code
Test
Result
Description / Recommendation
1002
ABORT
The system could not allocate timeslots for the test. The system may be under
heavy traffic conditions, or it may have timeslots out of service due to
TDM-BUS errors. Enter display errors and resolve any TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out of service.
1. Enter display errors and follow associated repair procedures for
TTR-LEV. Even if there are no TTR-LEV errors, there may not be a Tone
Detector available on the network that contains the circuit pack being
tested. Verify that there is at least one Tone Detector on this network. If
there is not at least one Tone Detector, this test always aborts for this EI
board. This will not harm the system.
2. Enter display errors and follow associated repair procedures for
TONE-PT.
3. If neither condition exists, retry the command at 1-minute intervals up to 3
times.
1015
ABORT
The system will not allow this test to be run because the EI circuit pack has not
been busied out.
1. Busyout the EI circuit pack. Then, repeat the test board UUCSS long
command.
1031
ABORT
If the EI circuit pack is in an PN and is on the active PNC, and is not part of an
PN-to-PN link, this test cannot be executed. If the lightwave transceiver
looparound is activated, it is impossible to deactivate it.
1. If PNC Duplication is enabled, attempt to make the standby PNC active
through the reset pnc interchange command.
2. If the PNC Interchange is successful, the Lightwave Transceiver
Looparound test may now be executed on the original EI circuit pack.
1033
ABORT
The test cannot run because the EI circuit pack does not have a fiber link
administered to it and there is not sufficient data to run the test.
1. Issue the list fiber-link command to verify that there is no fiber link
administered to this circuit pack.
2. If there is no fiber administered to this circuit pack (but should be), add the
correct fiber using the add fiber-link command.
3. Retry the command.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...