Maintenance-Object Repair Procedures
555-233-143
8-948
Issue 1 May 2002
Table 8-368.
Long IP 2Way Transmission Test (#1506)
Error
Code
Test
Result
Description / Recommendation
1002
ABORT
The system could not allocate timeslots for the test. The system may be under
heavy traffic conditions or it may have timeslots out of service due to TDM-BUS
errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals up to 3 times.
2. If system has TDM-BUS errors, clear any errors, and retry the command at
1-minute intervals up to 3 times.
3. If the command continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors. Even without TTR-LEV errors, a Tone
Detector could be unavailable in the PN containing the circuit pack being
tested. Verify that at least one Tone Detector resides in this PN. If not, the
test always aborts for this circuit pack, but does not harm the system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 3
times.
2000
ABORT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2012
ABORT
Generic system call failed. Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2801
ABORT
The IP Media processor board has not been administered on the ip-interfaces
form.
2804
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2806
ABORT
The system could not find any in-service IP Media processor boards to use as
a destination for this test.
2806
ABORT
The system could not find any in-service IP Media processor boards to use as
a destination for this test.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...