Maintenance-Object Repair Procedures
555-233-143
8-1060
Issue 1 May 2002
t. Error Type 3999—The circuit pack sent a large number of control-channel
messages to the switch within a short period of time.
Shutting Down NT on the TN802
Before removing the TN802 circuit pack from the carrier, shut Windows NT
TM
down first by following either procedure described in
:
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order they are presented in
. For example, by
clearing error codes associated with the NPE Connection Audit test (#50), you
may also clear errors generated from other tests in the testing sequence.
Error Type 1538
(hyperactivity)
also present?
Then the switch:
Y
Takes the circuit pack out-of-service due to hyperactivity
N
Does not take the circuit pack out-of-service, but the circuit
pack has generated 50% of the messages necessary to be
considered hyperactive. This may be normal during heavy
traffic periods.
Table 8-420.
Windows NT shutdown procedures
Step
Faceplate button
PC interface
1.
Push the recessed button on the front
faceplate and hold it in.
Click on the “Start” button in the lower
left-hand corner.
2.
“M shut” flashes on the LCD display
Click on “Shut Down.”
3.
When shutdown is complete, “MSHUT #”
displays (“#” is blinking).
Choose the “Shut down the computer?” radio
button.
4.
Remove the circuit pack.
Click on “OK.”
5.
Wait for the message indicating that shutdown
is complete.
6.
Remove the circuit pack.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...