Maintenance-Object Repair Procedures
555-233-143
8-1152
Issue 1 May 2002
Table 8-473.
Test #13 Analog Port Digital Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1000
ABORT
The port is in use on a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test call,
escalate the problem. To determine whether the port is in use by an ATMS
test call, enter status station ext where ext is the assigned ATMS
station’s number.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors. A system is considered under heavy traffic when the Call
Processing Occupancy is greater than 50% or when the System Management
and the Call Processing Occupancies together exceed 65%. To view the
system occupancy measurements enter the command status system health
on the system technician terminal.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 3 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 3
times.
1004
ABORT
The port was seized by a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test call,
escalate the problem. To determine whether the port is in use by an ATMS
test call enter status station ext, where ext is the assigned ATMS
station’s number.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...