PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1213
555-233-143
PE-BCHL (PRI Endpoint Port)
A PRI endpoint provides ISDN-PRI (Primary Rate Interface) connections
application equipment or terminal adapters that terminate ISDN PRI. The
equipment or terminal adapters are connected to the switch via the TN464C/D
UDS1 interface circuit pack. This MO monitors the PRI endpoint’s port hardware
on the UDS1 circuit pack by:
■
Logging hardware errors
■
Running tests for port initialization
■
Running periodic and scheduled maintenance
■
Executing demand tests
Wideband Switching
Wideband switching supports end-to-end connectivity between customer
endpoints at data rates from 128 to 1536 kbps over T1 facilities and to 1984 kbps
over E1 facilities. S8700 Multi-Connect switching capabilities support wideband
calls comprised of multiple DS0s that are switched end-to-end as a single entity.
Wideband switching is designed for ISDN application equipment such as ISDN
video codecs, but can also interface to non-ISDN application equipment by using
PRI terminal adapters. In the same sense that a S8700 Multi-Connect data
module acts as a DCP or BRI terminal adapter between endpoint data such as
V.35 and dialing interfaces such as RS-366 and a DCP interface, a PRI terminal
adapter acts as a wideband terminal adapter between endpoint data and dialing
interfaces and S8700 Multi-Connect’s line-side ISDN-PRI interface. Wideband
switching introduces PRI endpoints on S8700 Multi-Connect line-side interfaces.
A PRI endpoint has a unique extension number and consists of one or more
contiguous B channels on a line-side T1 or E1 ISDN-PRI facility. Endpoints
initiate and receive calls via ISDN SETUP messages indicating the data rate and
specific B channels to be used, and communicate all other call status information
via standard ISDN messages. Any S8700 Multi-Connect ISDN signaling set such
as Avaya, CCITT, or ECMA may be used for a line-side ISDN-PRI facility.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command to
Run
1
1.
For additional repair information, see also UDS1-BD and Troubleshooting Wideband Problems in
Chapter 4, ‘‘Alarms, Errors, and Troubleshooting’’
Full Name of MO
PE-BCHL
MINOR
test port UUCSSpp l
PRI Endpoint Port
PE-BCHL
WARNING
test port UUCSSpp sh
PRI Endpoint Port
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...