PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1227
555-233-143
Service State Audit (#256)
As noted in the general description for PRI endpoint port, these ports may be in
one of several service states as defined by the ISDN-PRI Specification. This test
performs a service state audit with the far-end terminal adapter to ensure both
sides agree on the service state.
A PASS for this test simply means that an audit message was successfully
composed and sent out to the far-end terminal adapter. The ISDN Specification
allows up to 2 minutes for a reply. If no reply is received within that 2-minute
window, this switch will automatically try once again. If that attempt fails, an error
will be logged (Error Type 3073) and the switch will then attempt recovery by
automatically retrying approximately every 15 minutes. If the port was initially in
the INS (in-service) state, it will now be placed in the MTC/FE (maintenance state,
far-end problem) state. Until a Service State audit attempt is successful, no
outgoing calls will be placed over this port, but incoming calls will be accepted.
The service state of this port does not affect the service state of other ports in the
PRI endpoint. If an incoming call that uses this port is presented while in such a
state, a Service State audit attempt will immediately be attempted (that is, the
switch will not wait for the 15-minute cycle, but will instead try to recover
immediately). To investigate the status of this PRI endpoint port, issue the status
pri-endpoint extension command.
Table 8-502.
Test #256 Service State Audit Test
Error
Code
Test
Result
Description / Recommendation
1113
ABORT
The signaling link has failed, so the system cannot send any messages on
behalf of this port.
1. Check the results of Test #255 (Signaling Link State Check).
1117
ABORT
A service state audit message is outstanding.
1. Wait 2 minutes and then try again.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this PRI
endpoint extension is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled.
1. Either reconnect the disconnected PRI terminal adapter or disable the
rollabout video feature on this circuit pack. To do the latter, enter change
ds1 UUCSS and set the
Alarm when PRI Endpoint Detached?
field to y.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...