PMS-LINK (Property Management System Link)
Issue 1 May 2002
8-1277
555-233-143
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to the
extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
Table 8-517.
Test #215 Link Retry Test
Error
Code
Test
Result
Description / Recommendation
10, 20
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30
ABORT
Internal system error.
1. Refer back to
‘‘Procedures for Restoring the PMS Link’’ on page 8-1271
for
resolution.
1010
ABORT
The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
state.
2. Retry test pms command to execute the test.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The PMS Link CANNOT be established.
1. Refer back to
‘‘Procedures for Restoring the PMS Link’’ on page 8-1271
for
restoring the PMS Link.
PASS
The PMS Link is up.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...