Maintenance-Object Repair Procedures
555-233-143
8-1330
Issue 1 May 2002
Link Retry Test (#215)
This test sends a message to the CDR software process to make a data call to the
extension where the CDR output device connects to. If the CDR link is already
up, then this test will be passed without making any data call.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The CDR link is torn down.
Table 8-536.
Test #215 Link Retry Test
Error
Code
Test
Result
Description / Recommendation
10
ABORT
Internal system error.
20
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30
ABORT
Internal system error.
1. See
‘‘Procedures for Restoring the CDR Link’’
for instructions.
1010
ABORT
The CDR link has been busied out to out-of-service.
1. Enter release cdr primary | secondary command to release the CDR link
from busyout state.
2. Retry test cdr primary | secondary long command to execute the test.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The CDR link CANNOT be established.
1. See
‘‘Procedures for Restoring the CDR Link’’
for instructions.
PASS
The CDR link is up.
Continued on next page
Table 8-535.
Test #213 Link Tear Down Test
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...